What Data Centres Mean for Forever Chemicals (PFAS)

Can data centres reduce their PFAS footprint? Researchers assess alternatives, coolant recovery and waste treatment, including performance and safety trade-offs.
Fluorinated Molecules in a Blue Data Center

Artificial intelligence is reshaping industries, scientific research and everyday communication. Behind every chatbot response, generated image and complex computation, however, is a growing physical infrastructure of high-performance chips, servers and cooling systems. As investment in data centres accelerates, researchers are drawing attention to an environmental issue that has received less public scrutiny: the use and potential release of per- and polyfluoroalkyl substances (PFAS), widely known as forever chemicals, across the data centre supply chain.

A review published in Nature Reviews Clean Technology examines how PFAS enter data centre infrastructure, where releases may occur and which technologies could help capture, destroy or replace them. The article, titled “PFAS flows, treatment and reduction in data centre infrastructure”, is led by first author Bingzheng Wang and co-authored by researchers affiliated with Cornell University, Harvard University and ETH Zürich. The work is led from Cornell University’s College of Engineering, with contributions from Harvard’s John A. Paulson School of Engineering and Applied Sciences and ETH Zürich’s Institute of Biogeochemistry and Pollutant Dynamics.

The review does not report measurements of PFAS contamination around individual data centres. Instead, it maps potential uses and release pathways across semiconductor manufacturing, data centre cooling, and the disposal and recycling of electronic hardware. Its central message is that the expansion of artificial intelligence could amplify existing PFAS management challenges, making better monitoring, treatment and substitution strategies increasingly important.

Why the AI boom brings a chemical question

Data centres are expanding to meet demand for cloud computing, machine learning and generative AI. The review cites projections that installed data centre power requirements could rise from about 103 gigawatts in 2025 to 200 gigawatts by 2030. It also notes that AI workloads could account for around half of global data centre capacity by 2030, compared with approximately one-quarter in 2025.

This growth has implications beyond electricity demand. More computing capacity requires semiconductor chips, supporting materials, server components and thermal management systems. Higher rack power densities increase the challenge of removing heat, while rapid hardware development can shorten equipment lifetimes and increase electronic waste. PFAS are relevant because they are used in some of the materials and processes involved at several stages of this infrastructure.

PFAS are a broad group of synthetic organofluorine chemicals characterised by highly fluorinated carbon structures. Their chemical properties can provide useful performance characteristics, including resistance to heat and chemicals, low surface energy and specialised electrical or thermal properties. These functions have made certain PFAS valuable in industrial applications. Yet the strength and stability of carbon-fluorine bonds also contribute to the environmental persistence of many PFAS, and some members of the group are associated with adverse health and environmental effects.

From chip fabrication to server assembly

One important PFAS connection lies upstream, in semiconductor manufacturing. Advanced chips depend on highly controlled processes such as photolithography, plasma etching, wet chemical processing and chamber cleaning. In photolithography, materials must control surface tension, optical behaviour and acid-generation reactions so that extremely fine circuit patterns can be produced reliably.

The review describes the use of fluorinated surfactants, photoacid generators, antireflective coatings, barrier layers and fluorinated polymers in selected manufacturing applications. PFAS-containing photoacid generators can support the chemical reactions that change photoresist solubility during pattern formation. In immersion lithography, barrier layers can help prevent photoresist components from leaching into the immersion water. Fluorinated process gases, including CF4 and C4F8, are also used in plasma etching and equipment cleaning.

PFAS-containing materials may also be present in some semiconductor packaging materials, lubricants used in manufacturing equipment, cable insulation and connectors. Their roles differ across applications, and not every component or data centre uses the same PFAS-containing materials. The review therefore treats the data centre supply chain as a collection of distinct uses rather than a single source of chemical emissions.

During chip fabrication, PFAS may enter process wastewater, solvent residues, solid waste and atmospheric emissions. Plasma processes can fragment fluorinated gases and generate volatile fluorinated by-products. Wastewater may contain residues from photoresists, rinsing solutions, wet etching and cleaning. Contaminated filters, containers and equipment linings can contribute to solid waste streams. These routes underscore why PFAS management needs to consider multiple waste phases, not just wastewater.

Cooling powerful computers without losing control of fluids

The operational stage introduces another potential pathway. High-performance processors generate substantial heat, and advanced cooling systems are increasingly important in facilities with high rack power densities. Some two-phase immersion cooling configurations use fluorinated heat-transfer fluids. These fluids can absorb heat and transfer it through evaporation and condensation, supporting thermal management in densely packed computing systems.

Their use also raises questions about fluid containment and handling. Leakage, evaporation, maintenance activities, refilling and the disposal of spent coolant can create opportunities for release. The review highlights that opening or servicing systems containing volatile cooling fluids may result in emissions unless procedures are designed to contain and recover vapours. Closed-loop operation, careful maintenance and coolant recovery can reduce losses, although they require monitoring and appropriate infrastructure.

The authors discuss direct-to-chip cooling as one possible way to reduce reliance on large inventories of fluorinated immersion fluids. In these systems, coolant is delivered through cold plates or channels close to heat-generating components rather than immersing whole server assemblies. Some two-phase direct-to-chip designs may use substantially less coolant than immersion configurations and can limit fluid exposure during operation and servicing.

However, direct-to-chip cooling is not a universal or automatically PFAS-free solution. Flow control, coolant selection, thermal coverage, integration and long-term reliability remain engineering challenges. The choice of cooling architecture must balance heat removal, safety, operational reliability and environmental performance. Alternatives also need to be assessed for their own chemical hazards and life-cycle impacts.

The problem can continue after hardware is retired

PFAS management does not end when servers are removed from service. Electronic components can contain fluorinated polymers and other PFAS-containing materials. During disassembly, shredding, leaching, metallurgical recovery and waste treatment, these substances may be transferred into solid residues, liquid streams or gaseous emissions.

The review highlights estimates that hardware used to train and deploy large language models could generate 1.2 to 5.0 million tonnes of global electronic waste between 2020 and 2030. This estimate concerns e-waste associated with large language model hardware and should not be interpreted as a measured quantity of PFAS-containing waste. It nevertheless illustrates the scale of the hardware lifecycle challenge. Poorly managed electronic waste can create pathways for PFAS release, making traceability, responsible recycling and controlled disposal important parts of data centre sustainability.

Why capturing PFAS is not the same as destroying them

Treating PFAS-containing waste is technically difficult because the chemicals can occur in different physical forms and at different concentrations. The review describes treatment approaches that need to be matched to the characteristics of each waste stream. For wastewater, activated carbon adsorption and ion exchange can remove PFAS from water by transferring them onto a solid medium or resin. These are separation technologies: they concentrate PFAS in spent adsorbents or regenerant streams, which then require further management.

For concentrated liquid and solid wastes, high-temperature thermal treatment, including incineration, can achieve high destruction efficiencies. The review reports efficiencies above 99% for high-temperature thermal treatments, while emphasising their substantial energy requirements and the need for stringent emission controls. Destruction must be verified, and fluorinated by-products must be managed to avoid shifting pollution from one environmental compartment to another.

Gaseous PFAS streams may be treated using thermal oxidation or catalytic oxidation. Catalysts can lower the temperature needed for some gas-phase treatment processes, potentially reducing energy demand. Nevertheless, incomplete degradation and by-product formation remain concerns. Advanced oxidation and reduction processes in water can operate under milder conditions, but they may not achieve complete mineralisation and can generate transformation products. Emerging non-thermal and solvent-free approaches are promising in some studies, but the review notes that many remain technologically immature and have not been demonstrated at the scale needed for widespread industrial use.

The underlying chemical challenge is substantial. Carbon-fluorine bonds have bond energies of approximately 485 to 530 kilojoules per mole. Breaking these bonds and achieving complete mineralisation can therefore require intensive treatment. A successful PFAS strategy must distinguish between removing a compound from water, transforming its molecular structure and destroying it sufficiently to prevent problematic residuals.

Reducing PFAS at source

The review argues that downstream treatment alone cannot resolve the problem. Reducing PFAS use during manufacturing, limiting losses during cooling and preventing releases during recycling are also necessary. In semiconductor production, process optimisation and design changes could reduce the number of PFAS-dependent steps or the amount of material required. PFAS-free surfactants and alternative photoresist materials are being explored, although performance and compatibility requirements make substitution difficult in some advanced applications.

Cooling systems offer opportunities for better containment, coolant reuse and alternative fluids or architectures. Reuse and regeneration can reduce the need for fresh coolant and limit the volume requiring disposal. Such approaches require reliable fluid monitoring, maintenance protocols and recovery systems. Any proposed replacement must also meet demanding requirements for thermal performance, electrical properties, material compatibility and safety.

At the end-of-life stage, closed-loop material recovery and longer hardware lifetimes could reduce the demand for new chips and the amount of electronic waste generated. The authors also highlight cascaded use, in which servers or components are redeployed for less demanding workloads rather than discarded when they are no longer suitable for the most intensive tasks. Design for disassembly, take-back programmes and improved hardware traceability could support more responsible reuse and recycling.

The authors further point to system-level efficiency. Improvements in computing performance per watt can reduce energy use and thermal loads, potentially lowering cooling demand and the need for new hardware. Such measures do not directly eliminate PFAS, but they could reduce the scale of infrastructure and material demand associated with each unit of computation.

A growing need for data, monitoring and accountability

A major limitation identified by the review is the lack of detailed, application-specific data on PFAS flows across the data centre value chain. The authors do not present a complete quantitative inventory of PFAS use or emissions, nor a quantitative life-cycle assessment of data centre infrastructure. Better information is needed to identify high-emission processes, compare technologies and establish priorities for substitution and treatment.

The review calls for greater supply-chain transparency, clearer reporting of PFAS use and releases, and monitoring of wastewater, air emissions, spent fluids, and solid residues. It also highlights the influence of regulation. Restrictions and application-specific exemptions can affect how quickly manufacturers replace PFAS in semiconductor processes and cooling systems. Even where certain uses remain permitted, downstream emission controls and waste-management requirements remain important.

For the technology sector, the implications extend beyond compliance. Data centre operators, chip manufacturers, equipment suppliers and recyclers all influence PFAS use and release at different stages. Coordinated action is needed to establish material inventories, qualify safer alternatives, contain cooling fluids and ensure that retired hardware is managed responsibly.

The future of AI infrastructure must include chemical sustainability

The review by Bingzheng Wang and colleagues presents PFAS as an overlooked dimension of the environmental footprint of artificial intelligence. It does not claim that data centres have been demonstrated to be major sources of PFAS contamination, and it identifies substantial gaps in the data needed to quantify emissions. Its contribution is to map where PFAS are used, how they could move through the infrastructure lifecycle and which control measures may reduce their release.

As AI infrastructure expands, sustainability assessments will need to look beyond electricity and water consumption. The materials used to manufacture chips, the fluids used to cool servers and the fate of electronic components after use are also part of the environmental equation. Better PFAS monitoring, verified destruction technologies, safer material substitution and circular approaches to hardware could help reduce the chemical footprint of data centres.

Reference

Wang, B., Elgamal, M., Hills, G., Scheringer, M., & You, F. (2026). PFAS flows, treatment and reduction in data centre infrastructure. Nature Reviews Clean Technology. https://doi.org/10.1038/s44359-026-00232-8

Key Insights

PFAS enter data centres through chipmaking, cooling and electronic waste.
Fluorinated cooling fluids can create potential PFAS release pathways.
PFAS capture does not necessarily mean complete chemical destruction.
High temperature treatment can achieve over 99% destruction efficiency.
Safer alternatives and better monitoring are essential for sustainable AI.

Copyright © The Science Matters

This article is licensed under the Creative Commons Attribution-NonCommercial 4.0 International Licence (CC BY-NC 4.0).

You are free to share, copy, redistribute, and adapt this material in any medium or format for non-commercial purposes, provided appropriate credit is given to the author and The Science Matters, a link to the licence is provided, and any changes made are indicated.

Related Articles

Subscription Form